Learning objectives
After the lesson the participant can:
- Explain why a small global share of electricity can still be a decisive local load.
- Compare the footprint of training with that of inference and name the choices that change inference by orders of magnitude.
- Identify what the Energy Efficiency Directive and Annex XI of the AI Act require to be reported and the gap they leave for deployers.
- Draft a routing policy that defaults to the smallest adequate model and reports energy, carbon and water per functional unit.
Key concepts
- Smallest adequate model
- The series' principle of choosing the smallest model that meets the acceptance criteria. Adequacy is established by running the evaluation suite against at least two model sizes for each request class.
- Functional unit
- The unit the service is managed by, such as a resolved enquiry or a completed agent task. For agents that make many model calls, energy per completed task is the relevant unit.
- Rebound effect
- Lower energy per request lowers cost, and lower cost invites more requests. A budget for the service as a whole, not only an efficiency target per request, makes rebound visible.
- Annex VII figures
- Under Article 12 of the recast Energy Efficiency Directive, data centres with at least 500 kilowatts of installed IT power publish yearly figures including energy consumption, power utilisation, waste-heat utilisation, water use and renewable energy.
- The reporting gap
- The Directive reports buildings, not workloads, and the AI Act's documentation concerns the model. Neither requires anyone to state the energy, carbon or water of an inference request, so deployers still estimate, stating method and limitations.
Interactive exercises
Do them here and get feedback at once. Choose a card and then where it belongs, or drag it.
Interactive exercise 1 · Put in order
The physical path of a request
Put the steps by which an AI request becomes energy, carbon and water in the order of the chapter's figure.
Interactive exercise 2 · Scenario
Drift towards the larger model
Apply the routing policy with carbon reporting for Hansa Mutual's claims assistant.
Teaching plan
| 10 min | The teacher follows one AI request along Figure 17.1 from model to accelerators, grid and cooling, with the IEA estimates and the reasons the load is concentrated. |
| 10 min | Review water, materials and the shift from training to inference; participants rank common tasks by energy per request as the measurements found. |
| 10 min | Explain the two reporting regimes, the gap between them and the five groups of choices, ending with the caution on rebound. |
| 22 min | Exercise in pairs: write a routing policy with footprint reporting for one AI service, modelled on RP-HM-CLAIMS-2026-02, and list the disclosures to request from suppliers. |
| 8 min | Stage the debate on trajectory against share and review the verdict on the physical form of T8. |
Discussion
- Both sides of the debate rely on the same IEA report. What does each emphasise, and what additional disclosure would let a local council decide between them for a proposed data centre?
- The guide says that where a service affects people's rights, quality comes first and the footprint is optimised within it. Where is that boundary for the services you run?
- The chapter argues that physical constraints arrive slowly and visibly, as prices and delays. How would your organisation notice such a constraint early, and what would it do first?
Written exercise
Exercise · 22 minutes
A routing policy with a footprint record
Choose one AI service you run or use. Name its functional unit. Divide its requests into two or three classes and, for each, name the smallest model you believe is adequate and the evidence you have or would need. Write the default route with an output limit and a caching rule, and the declared, logged condition for escalating to a larger model. List any flexible work that could be scheduled for the cleanest hours. Set a monthly energy budget, the metrics to report and the method for estimating them, stating its limitations. Add two review triggers and the supplier figures you will request, noting what a refusal would tell you.
Deliverable: A routing policy with request classes, default and escalation rules, an energy budget, reporting metrics with method, review triggers and supplier requests.
Self-test
Choose an answer to see whether it is right, or open the answer below each question.
What did the International Energy Agency estimate for data centres in its April 2025 report?
Show the answer
A. About 1.5 per cent of global electricity in 2024, more than doubling by 2030 in its base case
The IEA estimated around 415 terawatt-hours in 2024 and a little under 3 per cent of global consumption by 2030, with wide uncertainty and AI as the main driver.What did Luccioni, Jernite and Strubell find when they measured inference across models and tasks?
Show the answer
C. Differences of several orders of magnitude, with image generation the most energy-intensive
Classifying text used very little energy, generating text much more and generating images the most, which is why the inference footprint is the sum of deployer decisions.How does the verdict grade the full physical form of T8, a society whose AI stops for physical reasons and that can no longer function without it?
Show the answer
B. It remains fiction, and a forecast that it will happen is speculation
Rising use is a pattern at scale and local strain an incident in the wild in some regions, but physical constraints arrive slowly and visibly, which gives institutions time to respond.